Correct for signal, native bridge test hard-coded signal handling values

Added inline assembly to ensure that the instruction causing a segfault
in x86/x86_64 for the 004-SignalTest and 115-native-bridge test always
has a size of 3 bytes, in response to a bug that caused the test to fail
when this instruction had variable sizes.

Bug: 22876261
Change-Id: I474a04782a446439956c22360c71cea2655f8a1b
diff --git a/test/115-native-bridge/nativebridge.cc b/test/115-native-bridge/nativebridge.cc
index 04326b3..702e779 100644
--- a/test/115-native-bridge/nativebridge.cc
+++ b/test/115-native-bridge/nativebridge.cc
@@ -206,8 +206,9 @@
 #if defined(__arm__) || defined(__i386__) || defined(__aarch64__)
   *go_away_compiler = 'a';
 #elif defined(__x86_64__)
-  // Cause a SEGV using an instruction known to be 3 bytes long
-  asm volatile("movl $0, %%eax;" "movb $1, (%%eax);" : : : "%eax");
+  // Cause a SEGV using an instruction known to be 3 bytes long to account for hardcoded jump
+  // in the signal handler
+  asm volatile("movl $0, %%eax;" "movb $1, (%%al);" : : : "%eax");
 #else
   // On other architectures we simulate SEGV.
   kill(getpid(), SIGSEGV);