commit | fda5114f0d4d4b4ecfd891ad6a57af16cbd8f54c | [log] [tgz] |
---|---|---|
author | Badhri Jagan Sridharan <Badhri@google.com> | Tue Oct 27 10:43:53 2015 -0700 |
committer | Ruchi Kandoi <kandoiruchi@google.com> | Thu Feb 25 12:15:54 2016 -0800 |
tree | 5ed33680adcfc273858676c19b1d81143f9700a9 | |
parent | 6f9684ee07908119711cd2be022ba03feb0314eb [diff] |
healthd: Read the max power supply voltage With Type-C PD, VBUS can no longer be assumed to to be at 5V. Read the "voltage_max" field from the power_supply class node and export it through BatteryProperties service. Bug: 25229483 Change-Id: I04e32d9783a21bab375f1724758a9eeace2a047c