IOT specific changes to delay/reduce timeout for Autoconnection.

Delay Connect Other Profile timeout.

Some devices namely Volkswagen UHV reject DUT initiated connection
when DUT tries to connect other auto-connectable profile 6s after
peer connects the first one. To avoid such race condition, raised
connect other profile timeout to 10s to make sure there is no
connection rejection from remote because of connection collision.

Change-Id: I676b98ae64085a45bd6ecb9a6aeac7921a009e84

Reduced timeout delay for Autoconnection.

As per the implementation for the incoming connection scenario if one
profile got connected and other profile didn't get connected, DUT starts
connect other profiles after 6sec timeout. For this particular carkit
this timeout has been reduced to 2sec for triggering Auto connect to
otherprofiles from DUT. So that Audio will get routed to BT device with
reduced delay.

Change-Id: Ic946897d2260c2d50cc8f228456f4f2af5c6943c

CRs-Fixed: 2333734
Change-Id: Ib1daff9c80cfb1930fdc379e5efa61dda4f0ce3f
1 file changed